EG-840T Therapeutic Gastroscope


The EG-840T therapeutic gastroscope features a CMOS sensor and provides a unique 160 degrees down-angulation to also access difficult-to-reach areas. The working channel diameter of 3.2 mm provides a good balance of suction performance and control of the inserted instrument, making it very suitable for advanced therapeutic interventions like ESD.

Let us help you find the right product or service that will suit your needs.

TECH SPEC

EG-840T Specification

Characteristics
Water Jet, Working length of 1,100 mm
Observation Range
2-100 mm
Field of view
140°
Diameter distal end
9.8 mm
Diameter insertion tube
9.8 mm
Diameter working channel
3.2 mm
Bending capability (up/down/left/right)
210°/160°/100°/100°
Features
  • CMOS Technology
  • Water Jet Technology
  • Close Focus
  • ACI
  • G7 Grip
  • Advanced Force Transmission - Colo
  • Adaptive Bending - Colo
Benefits
  • CMOS Sensor: Delivers high-resolution imaging.
  • 160° Down-Angulation: Enables easier access to hard-to-reach areas.
  • G7 Grip: Comfortable grip for seamless handling.

Eluxeo 800 Series Product Comparison

Product

Observation Range

Field of view

Diameter distal end

Diameter insertion tube

Diameter working channel

Bending capability (up/down/left/right)

800 Series

Product

EG-840T

Observation Range

2-100 mm

Field of view

140°

Diameter distal end

9.8 mm

Diameter insertion tube

9.8 mm

Diameter working channel

3.2 mm

Bending capability (up/down/left/right)

210°/160°/100°/100°

Product

EG-840TP

Observation Range

2-100 mm

Field of view

140°

Diameter distal end

7.9 mm

Diameter insertion tube

7.9 mm

Diameter working channel

3.2 mm

Bending capability (up/down/left/right)

210°/160°/100°/100°

Product

EG-840N

Observation Range

2-100 mm

Field of view

140°

Diameter distal end

5.8 mm

Diameter insertion tube

5.9 mm

Diameter working channel

2.4 mm

Bending capability (up/down/left/right)

210°/90°/100°/100°

Product

EG-860R

Observation Range

2-100 mm

Field of view

140°

Diameter distal end

8.9 mm

Diameter insertion tube

8.9 mm

Diameter working channel

2.8 mm

Bending capability (up/down/left/right)

210°/120°/100°/100°

Product

EC-860S/M

Observation Range

2-100 mm

Field of view

170°

Diameter distal end

12.8 mm

Diameter insertion tube

12.8 mm

Diameter working channel

3.8 mm

Bending capability (up/down/left/right)

180°/180°/160°/160°

Product

Observation Range

2-100 mm

Field of view

170°

Diameter distal end

11.5 mm

Diameter insertion tube

11.5 mm

Diameter working channel

3.2 mm

Bending capability (up/down/left/right)

180°/180°/160°/160°

Product

Observation Range

2-100 mm

Field of view

170°

Diameter distal end

11.5 mm

Diameter insertion tube

11.5 mm

Diameter working channel

3.2 mm

Bending capability (up/down/left/right)

180°/180°/160°/160°

Product

Observation Range

2-100 mm

Field of view

170°

Diameter distal end

12.8 mm

Diameter insertion tube

12.8 mm

Diameter working channel

3.8 mm

Bending capability (up/down/left/right)

180°/180°/160°/160°

Product

Observation Range

2-100 mm

Field of view

170°

Diameter distal end

12.8 mm

Diameter insertion tube

12.8 mm

Diameter working channel

3.8 mm

Bending capability (up/down/left/right)

180°/180°/160°/160°

Product

Observation Range

2-100 mm

Field of view

170°

Diameter distal end

12.8 mm

Diameter insertion tube

12.8 mm

Diameter working channel

3.8 mm

Bending capability (up/down/left/right)

180°/180°/160°/160°

Product

Output

Input

External memory

Power rating

Dimensions (W x H x D)

Weight

Compatibilty

Product

EP-8000

Output

12G-SDI, 3G-SDI, DVI-D, RGB-TV

Input

Digital 2 channel PoP

External memory

USB Flash Drive

Power rating

100 – 240V, 50 / 60Hz, 3.0 – 1.5A

Dimensions (W x H x D)

395 x 210 x 515 mm

Weight

18.0 kg

Want to know more? Get in Touch